Contact us

Use our convenient email form to communicate directly with Ciena

Send Email
 
 

Search results

1 - 10 of 48 Search Results for Alarm
  • ….14 Cubic meter/minute (4 fans 0.286 m3/min each) Hot-pluggable Environmental alarms and visual indicators One input and one output environmental and office alarm Three system-level LEDs for Critical, Major and Minor alarm indications Mounting options 19", ETSI and 23" Rack Mountable Environmental Market…
  • FC4-T Fibre Channel Muxponder Module
    …from FC client 1 to 3. The aggregated data stream is then mapped into OTU-2 frames, complete with the OTU-2 header for performance monitoring and alarming, plus Forward Error Correction (FEC) to improve transmission performance over lengthy or degraded spans. The result is a standard OTU-2  frame…
  • …Transmission Unit MUX Multiplexer MUXCVR Muxceiver mV Millivolt MVOA Miniature Variable Optical Attenuator MW MultiWave® MZ Mach-Zehnder N NA No Alarm; Not Alarmed; Not Applicable; Not Available; Numerical Aperture NAD Network Access Domain NAP Network Access Point NAPT Network Address and Protocol Translation…
  • …for non-blocking switching Dedicated control interfaces between Control     Modules and each Line Module Alarm Module with interface to external alarms Power Requirements DC Voltage Input Range: -40V to -57V DC Power Draw for fully loaded system: - Typical power: 3,750 Watts - Maximum…
  • …operating system     kernel, load modules, alternate images,     configuration files Alarm Module with interface to external alarms Power Requirements AC Voltage Input Range: 100V to 240V AC AC Line Frequency Input Range: 50Hz to 60 Hz Maximum Power Input: 1000…
  • …on relatively short lines. AIS (Alarm Indication Signal) A signal, transmitted by a system within a communications link, which lets the receiver know that some part of the link has failed. Two types of AIS signals are Alarm Indication Signal Path (AIS-P) and Alarm Indication Signal Line (AIS-L). American…
  • …Optical Service Channel 2.048 Mb/s at 1625 nm (ULH applications), 100 Mb/s at 1510 nm (regional applications) Remote Alarm Outputs 16 Form C contact closures (ULH application only) Remote Alarm Inputs 32 Form C or Form A contact closures (ULH application only) Voice Orderwire Digital and analog capability…
  • …    or 2 port OC-48/STM-16 CEP (SFP) 24 port T1/E1 TDM SAToP 1 port 10GbE (SFP+) FTM interfaces Four alarm input dry-contacts and three     alarm output dry-contacts Switch Throughput Capacity 84 Gb/s full duplex Redundancy and Protection Redundant power supplies…
  • …interface) IP/802.3 via 10BaseT or 10Base2, OSI/LLC1/802.3 via 10BaseT or 10Base2 Optical Service Channel 2.048 Mb/s at 1625 nm External Alarm Management 32 alarm inputs 16 control outputs (FORM-C) Voice Orderwire Digital and analog capability, 2 × 64 Kb/s channels, 2 wire or 4 wire interface Power…
  • F10-T 10G Transponder Module
    …also provides the system controller function for the 4200® MC 2-slot and 4200 5-slot Advanced Services Platforms to govern system provisioning, alarm monitoring, and communication with Ciena’s ON-Center® Network and Service Management Suite. The F10-T is equipped with two full-duplex optical…